Applicable fibers |
PM
(PANDA, Bowtie, TIGER), SM, MM, NZDS, DS,
Large diameter fiber, Reduced cladding fiber |
|
Fiber
count |
Single |
|
Cladding
diameter |
80mm to
400mm |
|
Coating
diameter |
100mm to
1,000mm |
|
Fiber
cleaved length |
8mm to
10mm (standard)
3mm to 5mm (short cleaved length) |
|
Actual
average splice loss |
0.06dB
with PANDA, 0.06dB with TIGER, 0.06dB with Bowtie,
0.02dB with SM, 0.01dB with MM, 0.04dB with DS |
|
Average
cross talk |
-40dB
with PANDA, -32dB with TIGER, -29dB with Bowtie |
|
Splice
time |
45sec
with PANDA, 90sec with TIGER, 110sec with Bowtie,
20sec with SM |
|
Return
loss |
>>60dB |
|
Splicing
modes |
40 user
programmable modes and
120 database area (factory predetermined setting) |
|
Splice
loss estimate |
Available |
|
Attenuation splice function |
0.1dB to
25dB |
|
Storage
of splice result |
The last
1,200 splices to be stored in the internal memory |
|
Fiber
display |
X/Y, or X
and Y simultaneously |
|
Magnification |
270x for
single X or Y view, or 135x for X and Y view |
|
Viewing
method |
Two CCD
cameras and 5 inch TFT color LCD monitor |
|
Operating
condition |
0 to
3,500m above sea level
0 to 95%RH and 0 to 40 degree C respectively |
|
Mechanical proof test |
2.45N |
|
Tube
heater |
Built-in
tube heater with 10 heating modes and 20 database area |
|
Tube heat
time |
Typical
100sec with FP-03 protection sleeve
Typical 70sec with series of micro sleeves |
|
Applicable protection 60mm, sleeve length |
60mm,
40mm, and a series of micro sleeves |
|
Power
supply |
Auto
voltage selection from 100 to 240Va.c. with ADC-10,USB 1.1 (type B) and
RS232C for PC communication
GP-IB port for power monitor feedback alignment
Video terminal RCA video jack / NTSC |
|
Wind
protection |
Max. wind
velocity of 5m/s. |
|
Dimensions |
311W x
218D x 234H (mm) in operation |
|
Weight |
6.1kg
without AC adapter |