Fujikura FSM-60S
The FSM-60S fusion splicer sets the
standard for core alignment fusion splicing by incorporating a user-friendly
interface with enhanced features to provide the most rugged and reliable
fusion splicer in the market today. The new rugged construction adds
improved reliability by resisting shock, dust, and rain,
and can withstand a
30 drop test.The
FSM-60S splices a fiber in 9 seconds and heats a
60mm splice sleeve in 30 seconds, for a total cycle time of
only 39 seconds. New features, such as automatic tube heater operation,
user-selectable clamping method (sheath clamp or fiber holder system),
automated monitor image orientation, and battery charge capability during
splicer operation provide the end user a productivity tool they can count on.New
software included provides the ability to download splice data to a PC for
splice data reporting, download splicer operating software via the internet to
maintain peak performance, and download video images from the splicer to
enhance technical support.
Features
1)
Rugged construction providing shock, dust and moisture resistance
2) Dual monitor position with automatic image orientation
3) Automatic arc calibration and fiber identification
4) User-selectable fiber clamping method - sheath clamp or fiber holders
5) Auto-start tube heater feature
6) Color LCD display with anti-reflective coating for excellent visibility in
bright sunlight
7) Simultaneous battery charge and splicer operation
8) Long life battery (up to 160 splice/heat cycles per charge)
9) Detachable work table incorporated into the transit case
10) Data and video download software included; software upgrade available via
the internet
11) Green friendly-RoHS & WEEE compliant
Specifications
|
Model |
FSM-60S Fusion Splicer |
|
Applicable Fibers |
Single-mode (ITU-T G.652),
Multimode (ITU-T G.651),
DS (ITU -T G.653), NZDS (ITU-T G.655) |
|
Cladding Diameter |
80um to150um |
|
Coating Diameter |
100um to 1,000um |
|
Fiber Cleave Length |
8 to
16mm with 250um coating diameter,
16mm with 900um coating diameter,Fonsun Technology |
|
Typical Average Splice Loss |
0.02dB with SM, 0.01dB with MM,
0.04dB with DS, 0.04dB with NZDS |
| |
Measured by cut-back method
relevant to ITU-T and IEC standards |
|
Splicing Time |
Typical 9 seconds with standard
single-mode fiber |
|
Arc Calibration Method |
Automatic, real-time and by
using results of previous splice when in AUTO mode, manual arc calibration
function available |
|
Splicing Modes |
100 preset and user
programmable modes |
|
Splice Loss Estimate |
Based upon dual camera core
alignment data |
|
Storage of Splice Result |
Last 2000 results to be stored
in the internal memory |
|
Fiber Display |
X or Y, or both X and Y
simultaneously. Front or rear monitor display options with automated image
orientation |
|
Magnification |
300X for single X or Y view, or
187X for X and Y view |
|
Viewing Method |
Dual cameras with 4.1 inch TFT
color LCD monitor |
|
Operating Condition |
0 to
5,000m above sea level, 0 to 95%RH and -10 to
50 respectively |
|
Mechanical Proof Test |
1.96 to 2.25N |
|
Tube Heater |
Built-in tube heater with 30
heating modes; auto-start function |
|
Tube Heating Time |
Typical 30 seconds with FP-03
sleeve, 35 seconds with FP3 (40), 35-55 seconds with Fujikura micro
sleeves ,Fonsun Technology |
|
Protection Sleeve Length |
60mm,
40mm, micro |
|